Operating Manual for 
mp6-XEVA Board 

 

 

Содержание microComponents mp6-XEVA

Страница 1: ...1 Rev 1 0 04 2020 Operating Manual for mp6 XEVA Board ...

Страница 2: ...suse 4 Staff selection and qualification 4 About this operating manual 4 The mp6 XEVA evaluation board 4 Safety notice 5 Electrical specifications mp6 XEVA evaluation board 5 Functional elements 5 Operation 6 Pump frequency setting with jumper JP1 6 Pump amplitude setting with jumper JP2 7 Operation voltage setting with jumper JP3 7 Connecting the pump via CON2 7 ...

Страница 3: ...the EU Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the micropumps Bartels Mikrotechnik can assume no liability for damages resulting from the pump media This applies especially for hazardous fluids The pumps must be operated with Bartels Mikrotechnik electronics ...

Страница 4: ...troller must be carried out by qualified suitably trained and instructed personnel Work on electrical components and assemblies must be carried out by personnel with the necessary qualifications and skills About this operating manual Warnings and important notes are clearly identified as such in the text The relevant text sections feature a specific sign However this icon cannot replace the safety...

Страница 5: ... carry high voltage Be careful WHILE CONNECTING AND HANDLING THE BOARD Electrical specifications mp6 XEVA evaluation board As the evaluation board is based on the mp6 XOEM module all electrical characteristics and specifications of this product must be considered Please have a look at the corresponding manual for more details Functional elements 1Elements are listed with their names according to t...

Страница 6: ...e connector the pump needs to be inserted with its metallic contacts upwards Step 2 Choose the pump frequency setting with Jumper 1 Step 3 Choose the pump amplitude setting with Jumper 2 Step 4 Choose the power supply setting with Jumper 3 CON 1 or USB port Step 5 Connect the board to the power supply Pump frequency setting with jumper JP1 Frequency defined by clock signal at Pin 3 CLK of screw te...

Страница 7: ...ort Connecting the pump via CON2 If the micropump of the mp6 series shall not be connected directly to the PCB with the Molex connector CON 3 an extension cable can be soldered directly to the connector CON 2 or a fitting Wire To Board connector like Molex PicoBlade Series 53047 can be used to attach an extension cable between the micropump and board The solder pads have the following pin assignme...

Страница 8: ...he pads next to the pins so the reset pin pin 15 is directly connected to the GND plane Referre to the mp6 XOEM manual for information about the I C interface The protocol is identical to the mp6 QuadOEM The screw terminals 5 and 6 can be used to connect the interface wires Please note that the address pins A0 and A1 are directly tied to GND on the mp6 XEVA so the slave address is fixed 2Bottom si...

Страница 9: ...l 49 231 47730 500 Fax 49 231 47730 501 Visit our Website http www bartels mikrotechnik de for further information on applications Tutorials and helpful answers to frequently asked questions can be found in our FAQ http blog bartels mikrotechnik de or on our YouTube channel https www youtube com user BartelsMikrotechnik Social Media Facebook Twitter Instagram LinkedIn ...