Proper use 

Intended purpose. 

The micropump is intended for pumping liquids or gases with varying flow rates controlled by the electronics. The 
controllers  are  intended  for  operating  the  micropumps.  Any  other  use  of  the  micropump  or  controller  unit  is 
deemed improper.  

Do not make any modifications or extensions to the pump or controller without the prior written consent of the 
manufacturer. Such modifications may impair the safety of the unit and are prohibited! Bartels Mikrotechnik GmbH 
rejects any responsibility for damage to the unit caused by unauthorized modifications to the pump and risk  and 
liability are automatically transferred to the operator. 

Misuse. 

The use of liquids, which may alone or in combination create explosive or otherwise health-endangering conditions 
(including vapors) is not permitted. 

Staff selection and qualification. 

All  work  in  connection  with  the  installation,  assembly,  commissioning/decommissioning,  disassembly,  operation, 
servicing, cleaning and repairing of the pump and the controller must be carried out by qualified, suitably trained 
and instructed personnel. Work on electrical components and assemblies must be carried out by personnel with the 
necessary qualifications and skills. 

About this operating manual. 

Warnings and important notes are clearly identified as such in the text. The relevant text sections feature a specific 
sign. However, this icon cannot replace the safety instructions. Therefore, carefully read all safety instructions in 
this manual.  Warnings and important notes in this text are highlighted as shown below, according to the severity 
of the damage that might result from non-compliance. 

 

 

DANGER

 

 

DANGER indicates a hazard with a high level of RISK THAT, if not avoided, will result in death or serious injury. 

The mp6-XEVA evaluation board 

The  evaluation  board  enables  the  simple  use  of  one  micropump  of  the  mp6-series  based  on  the  mp6-XOEM 
controller. Next to present standard parameter (250 Vpp,  200 Hz) the mp6-XEVA also allows to adjust the  pump 
parameters,  partly  by  external  tuning.  As  the  supply  voltage  of  the  module  can  be  provided  via  USB  (no  data 
interface), just attach it to a USB power supply and start the evaluation. Alternatively, it can also be supplied by a 
2.5 

 5 V power supply. 

Содержание microComponents mp6-XEVA

Страница 1: ...1 Rev 1 0 04 2020 Operating Manual for mp6 XEVA Board ...

Страница 2: ...suse 4 Staff selection and qualification 4 About this operating manual 4 The mp6 XEVA evaluation board 4 Safety notice 5 Electrical specifications mp6 XEVA evaluation board 5 Functional elements 5 Operation 6 Pump frequency setting with jumper JP1 6 Pump amplitude setting with jumper JP2 7 Operation voltage setting with jumper JP3 7 Connecting the pump via CON2 7 ...

Страница 3: ...the EU Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the micropumps Bartels Mikrotechnik can assume no liability for damages resulting from the pump media This applies especially for hazardous fluids The pumps must be operated with Bartels Mikrotechnik electronics ...

Страница 4: ...troller must be carried out by qualified suitably trained and instructed personnel Work on electrical components and assemblies must be carried out by personnel with the necessary qualifications and skills About this operating manual Warnings and important notes are clearly identified as such in the text The relevant text sections feature a specific sign However this icon cannot replace the safety...

Страница 5: ... carry high voltage Be careful WHILE CONNECTING AND HANDLING THE BOARD Electrical specifications mp6 XEVA evaluation board As the evaluation board is based on the mp6 XOEM module all electrical characteristics and specifications of this product must be considered Please have a look at the corresponding manual for more details Functional elements 1Elements are listed with their names according to t...

Страница 6: ...e connector the pump needs to be inserted with its metallic contacts upwards Step 2 Choose the pump frequency setting with Jumper 1 Step 3 Choose the pump amplitude setting with Jumper 2 Step 4 Choose the power supply setting with Jumper 3 CON 1 or USB port Step 5 Connect the board to the power supply Pump frequency setting with jumper JP1 Frequency defined by clock signal at Pin 3 CLK of screw te...

Страница 7: ...ort Connecting the pump via CON2 If the micropump of the mp6 series shall not be connected directly to the PCB with the Molex connector CON 3 an extension cable can be soldered directly to the connector CON 2 or a fitting Wire To Board connector like Molex PicoBlade Series 53047 can be used to attach an extension cable between the micropump and board The solder pads have the following pin assignme...

Страница 8: ...he pads next to the pins so the reset pin pin 15 is directly connected to the GND plane Referre to the mp6 XOEM manual for information about the I C interface The protocol is identical to the mp6 QuadOEM The screw terminals 5 and 6 can be used to connect the interface wires Please note that the address pins A0 and A1 are directly tied to GND on the mp6 XEVA so the slave address is fixed 2Bottom si...

Страница 9: ...l 49 231 47730 500 Fax 49 231 47730 501 Visit our Website http www bartels mikrotechnik de for further information on applications Tutorials and helpful answers to frequently asked questions can be found in our FAQ http blog bartels mikrotechnik de or on our YouTube channel https www youtube com user BartelsMikrotechnik Social Media Facebook Twitter Instagram LinkedIn ...

Отзывы: