5

 

Rev. 1.0 (04.2020)   

 

      

 

Safety notice. 

The mp6-XEVA generates voltages of up to 250 Vpp. 

All parts of the mp6-XEVA evaluation board can carry voltages 

in this range. Therefore, the board should only be used by  qualified personnel. Although the output power of the 
module  is  very  low, 

proper  insulation  according  to  the  application  conditions  needs  to  be  considered  by  the 

customer. 

This  especially  applies  to  the  lower  side  of  the  PCB.  Contact  with  water  or  other  liquids  needs  to  be 

prevented. The pump must not be changed while the board is powered. 

 

 

DANGER

 

 

The EVALUATION BOARD can carry high voltage! 

Be careful, WHILE CONNECTING AND HANDLING THE BOARD!

 

Electrical specifications mp6-XEVA evaluation board. 

As the evaluation board is based on the mp6-XOEM module, all electrical characteristics and specifications of this 
product must be considered. 

Please have a look at the corresponding manual for more details. 

Functional elements. 

 

 

1Elements are listed with their names according to the printed description on the PCB. 

Connectors: 

CON 1 

 Screw terminal for external power supply, external clock, amplitude signal, I²C-interface 

CON 2 

 Solder terminal for extension cable to connect one micropump of the mp6-series 

CON 3 

 Molex connector to connect one micropump of the mp6-series 

Mini USB connector for voltage supply via USB power supply, powerbank or computer 

 

 

Содержание microComponents mp6-XEVA

Страница 1: ...1 Rev 1 0 04 2020 Operating Manual for mp6 XEVA Board ...

Страница 2: ...suse 4 Staff selection and qualification 4 About this operating manual 4 The mp6 XEVA evaluation board 4 Safety notice 5 Electrical specifications mp6 XEVA evaluation board 5 Functional elements 5 Operation 6 Pump frequency setting with jumper JP1 6 Pump amplitude setting with jumper JP2 7 Operation voltage setting with jumper JP3 7 Connecting the pump via CON2 7 ...

Страница 3: ...the EU Low Voltage Directive 2014 35 EU Description of functions The micropumps have been developed for the transport of gases or liquids The controllers have been developed for operating the micropumps Bartels Mikrotechnik can assume no liability for damages resulting from the pump media This applies especially for hazardous fluids The pumps must be operated with Bartels Mikrotechnik electronics ...

Страница 4: ...troller must be carried out by qualified suitably trained and instructed personnel Work on electrical components and assemblies must be carried out by personnel with the necessary qualifications and skills About this operating manual Warnings and important notes are clearly identified as such in the text The relevant text sections feature a specific sign However this icon cannot replace the safety...

Страница 5: ... carry high voltage Be careful WHILE CONNECTING AND HANDLING THE BOARD Electrical specifications mp6 XEVA evaluation board As the evaluation board is based on the mp6 XOEM module all electrical characteristics and specifications of this product must be considered Please have a look at the corresponding manual for more details Functional elements 1Elements are listed with their names according to t...

Страница 6: ...e connector the pump needs to be inserted with its metallic contacts upwards Step 2 Choose the pump frequency setting with Jumper 1 Step 3 Choose the pump amplitude setting with Jumper 2 Step 4 Choose the power supply setting with Jumper 3 CON 1 or USB port Step 5 Connect the board to the power supply Pump frequency setting with jumper JP1 Frequency defined by clock signal at Pin 3 CLK of screw te...

Страница 7: ...ort Connecting the pump via CON2 If the micropump of the mp6 series shall not be connected directly to the PCB with the Molex connector CON 3 an extension cable can be soldered directly to the connector CON 2 or a fitting Wire To Board connector like Molex PicoBlade Series 53047 can be used to attach an extension cable between the micropump and board The solder pads have the following pin assignme...

Страница 8: ...he pads next to the pins so the reset pin pin 15 is directly connected to the GND plane Referre to the mp6 XOEM manual for information about the I C interface The protocol is identical to the mp6 QuadOEM The screw terminals 5 and 6 can be used to connect the interface wires Please note that the address pins A0 and A1 are directly tied to GND on the mp6 XEVA so the slave address is fixed 2Bottom si...

Страница 9: ...l 49 231 47730 500 Fax 49 231 47730 501 Visit our Website http www bartels mikrotechnik de for further information on applications Tutorials and helpful answers to frequently asked questions can be found in our FAQ http blog bartels mikrotechnik de or on our YouTube channel https www youtube com user BartelsMikrotechnik Social Media Facebook Twitter Instagram LinkedIn ...