Overview of Alarms
11/2006
NCK alarms
2-92
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
8040
Machine data %1 reset, corresponding option is not set
Parameters:
%1 = String: MD identifier
Definitions:
A machine data has been set that is locked by an option.
Reaction:
Alarm display.
Remedy:
Please inform the authorized personnel/service department. For retrofitting the option, please refer to
your machine manufacturer or to a sales representative of SIEMENS AG, A&D MC.
Program
Continuation:
Clear alarm with the Delete key or NC START.
8041
Axis %1: MD %2 reset, corresponding option not sufficient
Parameters:
%1 = Axis number
%2 = String: MD identifier
Definitions:
All of the axes selected in the machine data of the assigned option are used. Safety functions have
been selected for too many axes in the axial machine data.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not
ready).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Remedy:
--
Program
Continuation:
Switch control OFF - ON.
8044
Option for IPO cycle time %1 ms not set
Parameters:
%1 = Impermissible IPO cycle time
Definitions:
The option for activation of an IPO cycle time of %1 ms has not been set.
Option - Permiss. IPO cycle time:
- Option-free >= 8ms
- 1. 1st step >= 6ms
- 2. 2nd step >= 4ms
- 3. 3rd step >= 2ms
- 4. 4th step <2ms
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
- Buy option
- Increase IPO cycle time (e.g. via MD IPO_SYSCLOCK_TIME_RATIO)
Program
Continuation:
Switch control OFF - ON.