Overview of Alarms
11/2006
NCK alarms
2-502
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61117
Channel %1 Block %2: Active tool radius <= 0
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The radius of the acive tool is negative or zero. Alarm triggered by following cycles: CYCLE71,
POCKET3, POCKET4.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Modify radius.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61118
Channel %1 Block %2: Length or width = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The length or width of the milling area is illegal. Alarm triggered by following cycle: CYCLE71.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check parameters _LENG and _WID.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61119
Channel %1 Block %2: Nominal or core diameter programmed incorrectly
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The nominal or core diameter was incorrectly programmed. Alarm triggered by following cycles:
CYCLE70, E_MI_TR, F_MI_TR.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check thread geometry.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61120
Channel %1 Block %2: Thread type inside / outside not defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The thread type (internal/external) was not defined. Alarm triggered by following cycles: CYCLE70.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
The internal/external thread type must be entered.
Program
Continuation:
Clear alarm with the RESET key. Restart part program