NCK alarms
11/2006
Overview of Alarms
2-283
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
16200
Channel %1 block %2 spline and polynominal interpolation not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The spline and polynomial interpolation are options that are not contained in the basic version of the
control.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Do not program spline and polynomial interpolation, or retrofit the necessary option.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16300
Channel %1 block %2 denominator polynominal with zero places within
parameter range not allowed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed denominator polynomial (with PL [ ] = ... , i.e. without specification of geometry axis)
has a zero place within the defined parameter range (PL = ...). This means that the quotient of the
numerator polynomial and the denominator polynomial is infinite or indeterminate.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify the polynomial block so that there is no zero place within the polynomial length in the
denominator polynomial.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16400
Channel %1 block %2 positioning axis %3 cannot participate in spline
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
An axis assigned to a spline grouping (n) with SPLINEPATH (n, AX1, AX2, ...) has been programmed
as positioning axis with POS or POSA.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Do not assign the positioning axis to the spline grouping.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16410
Channel %1 block %2 axis %3 is not a geometry axis
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
A geometry axis has been programmed that cannot be imaged on any machine axis in the current
transformation (possibly there is no transformation active at the moment).
Example:
Without transformation: Polar coordinate system with X, Z, and C axis
With transformation: Cartesian coordinate system with X, Y, and Z, e.g. with TRANSMIT.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Activate transformation type with TRAORI (n) or do not program geometry axes that do not participate
in the transformation grouping.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.