NCK alarms
11/2006
Overview of Alarms
2-495
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61014
Channel %1 Block %2: Return plane exceeded
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: CYCLE72.
Remedy:
Check parameter RTP.
61015
Channel %1 Block %2: Contour is not defined
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61016
Channel %1 block %2: System frame for cycles missing
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
All measuring cycles can trigger this alarm.
Remedy:
Set MD 28082: MM_SYSTEM_FRAME_MASK, Bit 5=1.
61017
Channel %1 block %2: function %4 not present in NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61018
Channel %1 block %2: function %4 not executable with NCK
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
Alarm triggered by following cycles: .
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Program
Continuation:
Clear alarm with the RESET key. Restart part program