NCK alarms
11/2006
Overview of Alarms
2-425
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
26015
Axis %1 machine data %2[%3] invalid value
Parameters:
%1 = Axis name, spindle number
%2 = String: MD identifier
%3 = Index: MD array
Definitions:
Machine data includes a value that is not valid.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Repeat entry with correct value and then Power On.
Program
Continuation:
Switch control OFF - ON.
26016
Axis %1 machine data %2 invalid value
Parameters:
%1 = Axis name, spindle number
%2 = String: MD identifier
Definitions:
Machine data includes a value that is not valid.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Repeat entry with correct value and then Reset.
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
26017
Axis %1 machine data %2[%3] invalid value
Parameters:
%1 = Axis name, spindle number
%2 = String: MD identifier
%3 = Index: MD array
Definitions:
Machine data includes a value that is not valid.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Mode group not ready, also effective for single axes
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Repeat entry with correct value and then Reset.
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.