NCK alarms
11/2006
Overview of Alarms
2-231
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
14401
Channel %1 block %2 transformation not available
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The required transformation is not available.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department.
- Modify part program; program defined transformations only.
- Check MD 24100 TRAFO_TYPE_n (assigns the transformation to part program instructions).
Program
Continuation:
Clear alarm with the RESET key. Restart part program
14402
Channel %1 block %2 spline active at transformation change
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
A change of transformation is not allowed in a spline curve section. A series of spline blocks must be
concluded.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14403
Channel %1 block %2 preprocessing and main run might not be
synchronized
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Positioning axis runs cannot be accurately calculated beforehand. Consequently, the position in the
MCS is not known exactly. It might therefore be possible that a change in the multiple significance of
the transformation has been performed in the main run although no provision was made for this in the
preprocessing run.
Reaction:
Alarm display.
Remedy:
Modify part program. Synchronize preprocessing run and main run.
Program
Continuation:
Clear alarm with the Delete key or NC START.