NCK alarms
11/2006
Overview of Alarms
2-195
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
14013
Channel %1 block %2 number of subroutine passes invalid
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
In a subroutine call the programmed number of passes P is zero or negative.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Program number of passes between 1 and 9 999.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14014
Channel %1 selected program %3 not available or will be edited
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
The selected parts program is not in the NCK memory or the access authorization for the program
selection is from a higher level than the current control status.
During creation, this program received the protection level of the NC control which was active at the
time.
In SW 5 or higher a program edited on HMI can no longer be started with NC Start.
The alarm will also be issued, if a file other than the specified definition file has been selected for the
GUD or macro definition.
Reaction:
Alarm display.
Remedy:
Reload the program in the NCK memory or check and correct the name of the directory (workpiece
overview) and the program (program overview) and reselect.
Program
Continuation:
Clear alarm with the Delete key or NC START.
14015
Channel %1 block %2 program %3 is not enabled
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Program name
Definitions:
The execution right currently set in the control (e.g. key switch position 0) is inadequate to execute
part program %3.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
- Raise the execution right to match the protection level of part program %3
- Assign a lower protection level to part program %3 or release (key switch protection level 0)
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.