Overview of Alarms
11/2006
NCK alarms
2-504
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61125
Channel %1 block %2: Technology selection in parameter _TECHNO
incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE84, CYCLE840.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check parameter _TECHNO.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61126
Channel %1 block %2: Thread length too short
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: CYCLE840.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Program lower spindle speed/raise reference plane.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61127
Channel %1 block %2: Wrong definition of tapping axis transformation
ratio (machine data)
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycles: CYCLE84, CYCLE840.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check machine data 31050 and 31060 in the appropriate gear stage of the drilling axis.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61128
Channel %1 block %2: Insertion angle = 0 for insertion with oscillation or
helix
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Alarm triggered by following cycle: SLOT1.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check parameter _STA2.
Program
Continuation:
Clear alarm with the RESET key. Restart part program