NCK alarms
11/2006
Overview of Alarms
2-501
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61113
Channel %1 Block %2: Parameter _CRAD too large for corner radius
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The parameter for the corner radius _CRAD has been specified too large. Alarm triggered by following
cycle: POCKET3.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Parameter must be reduced.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61114
Channel %1 Block %2: Machining direction G41/G42 incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The machining direction of the cutter radius compensation G41/G42 has been incorrectly selected.
Alarm triggered by following cycle: CYCLE72.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Change machining direction.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61115
Channel %1 Block %2: Approach or retract mode(straight / circle / plane /
space) incorrectly defined
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The approach or retract mode to/from the contour has been incorrectly defined. Alarm triggered by
following cycle: CYCLE72.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check parameter _AS1 or _AS2.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
61116
Channel %1 Block %2: Approach or retract path = 0
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The approach or retract path has been specified with zero. Alarm triggered by following cycle:
CYCLE72.
Reaction:
Alarm display.
Interface signals are set.
NC Start disable in this channel.
Interpreter stop
Remedy:
Check parameter _LP1 or _LP2.
Program
Continuation:
Clear alarm with the RESET key. Restart part program