Overview of Alarms
11/2006
NCK alarms
2-462
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
27024
Axis %1 stop A triggered
Parameters:
%1 = Axis number
Definitions:
This alarm follows an
- Alarm 27011 "Safe velocity exceeded" (when configured as such in
$MA_SAFE_VELO_STOP_MODE, $MA_SAFE_VELO_STOP_REACTION)
- Alarm 27013 "Safe braking ramp exceeded",
- Alarm 27023 "Stop B triggered"
- unsuccessful test stop.
The alarm can be reprogrammed in the MD ALARM_REACTION_CHAN_NOREADY (channel not
ready).
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Channel not ready.
Trigger a "Pulse suppression".
Remedy:
Eliminate causes of
- alarm "Save velocity exceeded",
- alarm "Safe braking ramp exceeded",
- alarm "Stop B triggered"
- unsuccessful test stop
(see description of these alarms).
Program
Continuation:
Switch control OFF - ON.
27030
Axis %1 function not supported on this 611D module
Parameters:
%1 = Axis number
Definitions:
SINUMERIK Safety Integrated can be used only with the 611D Performance control modules with 2
measuring circuits per drive and cutoff relay. An attempt has been made to activate a safety function
although no such module is plugged in.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Replace module or switch off safety functions in MD $MA_SAFE_FUNCTION_ENABLE.
Program
Continuation:
Switch control OFF - ON.