NCK alarms
11/2006
Overview of Alarms
2-249
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
14753
Channel %1 block %2 motion synchronous actions with illegal
interpolation type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The active interpolation type (e.g. 5-axis interpolation) is not allowed for the motion synchronous
action or for the function "Several feeds".
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14754
Channel %1 block %2 motion synchronous actions and wrong feed type
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The active feed type is not allowed for the motion synchronous action or for the function "Several
feeds".
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14755
Channel %1 block %2 motion synchronous actions without traverse
motion
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed motion synchronous action and the function "Several feeds" require a traversing
motion or the value of the traversing motion is 0.
This alarm is no longer used after P3.2.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14756
Channel %1 block %2 motion synchronous action and wrong value
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Value of the synchronous action or the function "Several feeds" is not allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program. Check whether a negative value was entered for a synchronous action.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.