Overview of Alarms
11/2006
NCK alarms
2-592
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
68000
Channel %1 block %2:
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
References: The current alarm text, the error description and the remedial measures for the user cycle
alarms can be found in the Programming Guide of the machine manufacturer.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Refer to the manual on user cycles.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
69000
Channel %1 block %2:
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
References: The current alarm text, the error description and the remedial measures for the user cycle
alarms can be found in the Programming Guide of the machine manufacturer.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Refer to the manual on user cycles.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
70001
Channel %1 Yf is larger than distance C1-Cy
Parameters:
%1 = Channel number
Definitions:
In JOG mode, the Yf axis is traversed. The value of the Yf axis is larger than the distance C1-Cy
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Traverse Yf axis in JOG mode in opposite traversing direction
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.
70002
Channel %1 block %2 Yf has been programmed larger than distance C1-
Cy
Parameters:
%1 = Channel number
%2 = Block number
Definitions:
In the part program, one position in the Yf axis has been programmed larger than the distance C1-Cy
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with the RESET key in all channels of this mode group. Restart part program.