NCK alarms
11/2006
Overview of Alarms
2-83
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
6581
NC user memory full
Definitions:
The DRAM file system of the user area is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Continuation:
Clear alarm with the Delete key or NC START.
6582
NC machine OEM memory full
Definitions:
The DRAM file system of the machine OEM area is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Continuation:
Clear alarm with the Delete key or NC START.
6583
NC system memory full
Definitions:
The DRAM file system of the system area (Siemens) is full. The order cannot be executed.
Reaction:
Alarm display.
Remedy:
Delete or unload files (e.g. parts programs)
Program
Continuation:
Clear alarm with the Delete key or NC START.
6584
NC memory limit TMP reached
Definitions:
The DRAM file system of the TMP (temporary) area is full. The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Increase machine date $MD_MM_DRAM_FILE_MEM_SIZE or switch off the precompilation of
individual or all cycles or, if need be,
delete the files in the TMP area.
Program
Continuation:
Clear alarm with the Delete key or NC START.
6585
NC external memory limit reached
Definitions:
The DRAM file system of the external area (execution of the external drive) is full.
The job cannot be executed.
Reaction:
Alarm display.
Remedy:
Load the files to be executed explicitly into the NCK.
Program
Continuation:
Clear alarm with the Delete key or NC START.
6600
NC card memory is full
Definitions:
The NC card file system of the NCK is full. No more data can be stored on the NC card.
Reaction:
Alarm display.
Remedy:
Delete the data on the PCMCIA card.
Program
Continuation:
Clear alarm with the Delete key or NC START.
6610
Too many files open on NC card
Definitions:
Too many files are being accessed simultaneously on the NC card.
Reaction:
Alarm display.
Remedy:
Repeat the action later.
Program
Continuation:
Clear alarm with the Delete key or NC START.