SIMODRIVE alarms
11/2006
Overview of Alarms
2-785
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
310703
Axis %1 drive %2 monitoring cycle time invalid
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
Monitoring cycle MD 5002: MONITOR_CYCLE_TIME (monitoring cycle) is invalid.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please refer to the drive functions "FB/DB1" MD 1002.
Program
Continuation:
Switch control OFF - ON.
310704
Axis %1 drive %2 speed controller cycle times of axes differ
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The speed controller cycle MD 5001: SPEEDCTRL_CYCLE_TIME must be identical for both axes on
2-axis modules.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Set an identical speed controller cycle MD 5001: SPEEDCTRL_CYCLE_TIME for both axes.
Program
Continuation:
Switch control OFF - ON.
310705
Axis %1 drive %2 monitoring cycle times of axes differ
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The monitoring cycle MD 5002: MONITOR_CYCLE_TIME must be identical for both axes on 2-axis
modules.
Reaction:
NC not ready.
The NC switches to follow-up mode.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Modify MD 5002: MONITOR_CYCLE_TIME for both axes.
Program
Continuation:
Switch control OFF - ON.