Overview of Alarms
11/2006
NCK alarms
2-224
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
14170
Channel %1 block %2 illegal interpolation type with tool length
compensation
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
If tool compensation (G43/G44) is activated in language mode ISO_2, the linear type of interpolation
must be active.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14180
Channel %1 block %2 H number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = H number of ISO mode
Definitions:
The specified H number is not assigned to a tool (ISO_2).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14185
Channel %1 block %2 D number %3 is not defined
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = D number of ISO mode
Definitions:
The specified D number is not assigned to a tool (language mode ISO_2).
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14190
Channel %1 block %2 H number with G49
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
G49 (select tool length compensation) and an H word not equal to H0 have been programmed
simultaneously.
Reaction:
Correction block is reorganized.
Local alarm reaction.
Interface signals are set.
Alarm display.
NC Stop on alarm at block end.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.