Overview of Alarms
11/2006
SIMODRIVE alarms
2-738
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
300748
Axis %1 drive %2 monitoring cycle times of both axes differ
Parameters:
%1 = NC axis number
%2 = Drive number
Definitions:
The monitoring cycles set in MD 1300: $MD_SAFETY_CYCLE_TIME (monitoring cycle) for the two
axes of a 2-axis module are not identical.
Request: During boot-up of the control.
Reaction:
Mode group not ready.
Channel not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy:
Please inform the authorized personnel/service department. Check and, if necessary, correct MD
1300: $MD_SAFETY_CYCLE_TIME (monitoring cycle) on all drives of the module.
Program
Continuation:
Switch control OFF - ON.