Overview of Alarms
11/2006
NCK alarms
2-272
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
15330
Channel %1 block %2 invalid block number as search target
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Syntax error! Positive integers are allowed as block numbers. Block numbers must be preceded by ":"
and subblocks by an "N".
Reaction:
Alarm display.
Remedy:
Repeat the input with corrected block number.
Program
Continuation:
Clear alarm with the Delete key or NC START.
15340
Channel %1 block %2 invalid label as search target
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
Syntax error! A label must have at least 2 but no more than 32 characters, and the first two characters
must be alphabetic or underscore characters. Labels must be concluded with a colon.
Reaction:
Alarm display.
Remedy:
Repeat the input with corrected label.
Program
Continuation:
Clear alarm with the Delete key or NC START.
15350
Channel %1 block %2 search target not found
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The specified program has been searched to the end of the program without the selected search
target having been found.
Reaction:
Interpreter stop
NC Start disable in this channel.
Interface signals are set.
Alarm display.
Remedy:
Check the part program, change the block search (typing error in the part program) and restart the
search.
Program
Continuation:
Clear alarm with the RESET key. Restart part program
15360
Channel %1 illegal target of block search (syntax error)
Parameters:
%1 = Channel number
Definitions:
The specified search target (block number, label or string) is not allowed in block search.
Reaction:
Alarm display.
Remedy:
Correct target of block search.
Program
Continuation:
Clear alarm with the Delete key or NC START.
15370
Channel %1 target of block search not found
Parameters:
%1 = Channel number
Definitions:
In a block search, an impermissible search target has been specified (e.g. negative block number).
Reaction:
Alarm display.
Remedy:
Check the specified block number, label or character string. Repeat entry with correct search target.
Program
Continuation:
Clear alarm with the Delete key or NC START.