NCK alarms
11/2006
Overview of Alarms
2-303
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
16780
Channel %1 block %2 following spindle/axis missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The following spindle/axis has not been written in the part program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16781
Channel %1 block %2 master spindle/axis missing
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The master spindle/axis has not been programmed in the part program.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16782
Channel %1 block %2 following spindle/axis %3 not available
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
A coupling has been switched on in which the slave spindle/axis is currently not available. Possible
causes:
- The spindle/axis is active in the other channel.
- The spindle/axis has been accessed by the PLC and has not yet been released.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Put the master spindle/axis with
spindle/axis exchange into the necessary channel or release from the PLC.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
16783
Channel %1 block %2 master spindle/axis %3 not available
Parameters:
%1 = Channel number
%2 = Block number, label
%3 = Axis name, spindle number
Definitions:
A coupling has been switched on in which the master spindle/axis is currently not available. Possible
causes:
- Setpoint linkage has been selected and spindle/axis is active in the other channel.
- The spindle/axis has been accessed by the PLC and has not yet been released.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Please inform the authorized personnel/service department. Put the master spindle/axis with
spindle/axis exchange into the necessary channel or release from the PLC.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.