Overview of Alarms
11/2006
NCK alarms
2-214
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
14122
Channel %1 block %2 angle and direction of the cone programmed
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With taper circumference interpolation of orientation with ORICONCW and ORICC, only the opening
angle or the direction of the taper may be programmed. Programming of both in one single block is
not allowed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14123
Channel %1 block %2 nutation angle of the cone too small
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With taper circumference interpolation, the programmed opening angle of the taper must be greater
than the half of the angle between the start and end orientation. Otherwise, a taper cannot be defined.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14124
Channel %1 block %2 start tangent for orientation is zero
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
With taper circumference interpolation with tangential continuation (ORICONTO), the start tangent of
orientation must not be zero.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.
14125
Channel %1 block %2 programmed rotation is not possible
Parameters:
%1 = Channel number
%2 = Block number, label
Definitions:
The programmed rotation of tool orientation cannot be traversed.
Reaction:
Correction block is reorganized.
Interface signals are set.
Alarm display.
Remedy:
Modify part program.
Program
Continuation:
Clear alarm with NC START or RESET key and continue the program.