NCK alarms
11/2006
Overview of Alarms
2-551
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
61428
Channel %1 block %2: Error while creating log file -> Error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy:
Causes of error:
1. Error code = A -> Number of log files in the current directory > 99
2. Error code = B -> Log files too long. Rename or delete log files,
check MD11420 $MN_LEN_PROTOCOL_FILE.
61429
Channel %1 block %2: Measuring axis (rotary axis 1 or 2) not in basic or
intended position -> Error code: %4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy:
Causes of error:
1. Error code = A -> Rotary axis 1 not in basic position on 1st measurement
2. Error code = B -> Rotary axis 2 not in basic position on 1st measurement
3. Error code = C -> Rotary axis 2 not in intended position on 2nd or 3rd measurement in
comparison to 1st measurement, see parameters _OVR[63 to 65]
4. Error code = D -> Rotary axis 1 not in intended position on 2nd or 3rd measurement in
comparison to 1st measurement, see parameters _OVR[60 to 62]
61430
Channel %1 block %2: Kinematic vectors not computed -> Error code:
%4
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycles: CYCLE996
Remedy:
Causes of error:
1. Error code = A -> Plausibility of the input points PM1, PM2, PM3 not fulfilled, resulting side
lengths must be not equal to zero
(Notice: even in the case of side lengths not equal to zero, there is a risk
of not being able to form a triangle => check PM1...3.)
2. Error code = B -> Enclosed angle at PM1 between the spread vectors PM1PM2 and PM1PM3
is equal to zero 0.
Starting points do not form a triangle.
3. Error code = C -> Enclosed angle at PM2 between the spread vectors PM2PM1 and PM2PM3
is equal to 0.
Starting points do not form a triangle.
4. Error code = D -> Enclosed angle at PM3 between the spread vectors PM3PM1 and PM3PM2
is equal to 0.
Starting points do not form a triangle.
5. Error code = E -> Normalizing interpolation point: Invalid axis name defined for computation
6. Error code = F -> Normalizing vertice: Invalid plane defined for computation
61440
Channel %1 block %2: Position of cutting edge cannot be determined
Parameters:
%1 = Channel number
%2 = Block number, label channel number
Definitions:
The alarm can be triggered by the following measuring cycle: CYCLE982
Remedy:
A turning tool with a cutting edge position between 1 and 8 must be used as the tool type.
Check the entered cutting edge position with reference to the basic position of the tool carrier.