Overview of Alarms
11/2006
NCK alarms
2-62
©
Siemens AG, 2006. All rights reserved
SINUMERIK, SIMODRIVE Diagnostics Manual (DA), 11/2006 Edition
4502
Channel %1 anachronism %2(%3) -> %4
Parameters:
%1 = Channel number
%2 = String: MD identifier
%3 = String: MD identifier
%4 = String: MD identifier
Definitions:
Previously, in $MC_RESET_MODE_MASK Bit4 and Bit5, the reset behavior of the 6th or 8th G
groupe was determined. This setting is now made in $MC_GCODE_RESET_MODE.
In order to ensure compatible handling of "old" data backups, the "old" values are taken from
$MC_RESET_MODE_MASK and entered in $MC_GCODE_RESET_MODE.
Reaction:
Alarm display.
Remedy:
--
Program
Continuation:
Clear alarm with the Delete key or NC START.
4503
In TO unit, %1 H number %2 assigned more than once. H number linked
again.
Parameters:
%1 = TO unit
%2 = H number
Definitions:
This error can only occur when MD $MN_MM_EXTERN_CNC_SYSTEM= 1 or 2. The Power ON
effective machine data bit 10890, $MN_EXTERN_TOOLPROG_MODE, bit 3 has been reset. On
reconstructing data handling after Power ON, it has been found that different edges of the same TO
unit have the same H number. They had been linked previously. They are linked again and MD bit
$MN_EXTERN_TOOLPROG_MODE, bit 3 is set again.
Reaction:
Alarm display.
Remedy:
H numbers must be assigned only once in a TO unit. Then, machine data bit 10890,
$MN_EXTERN_TOOLPROG_MODE, bit 3 can be set = 0 and a restart can be performed.
Program
Continuation:
Clear alarm with the Delete key or NC START.
4600
Invalid handwheel type for handwheel %1
Parameters:
%1 = Handwheel number
Definitions:
The handwheel type for handwheel %1 requested through machine date
$MN_HANDWHEEL_SEGMENT is invalid.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Configure a valid type for the corresponding handwheel through machine date
$MN_HANDWHEEL_SEGMENT.
Program
Continuation:
Switch control OFF - ON.
4610
Invalid handwheel module for handwheel %1
Parameters:
%1 = Handwheel module
Definitions:
The handwheel module for handwheel %1 requested through machine date
$MN_HANDWHEEL_MODULE is not available for 840D systems. An 840D system is always
regarded as a module. For this reason, handwheels directly linked with 840D systems
$MN_HANDWHEEL_MODULE = 1 must always be set.
Reaction:
Interface signals are set.
Alarm display.
Remedy:
Set machine date $MN_HANDWHEEL_MODULE = 1 for the corresponding handwheel.
Program
Continuation:
Switch control OFF - ON.