User Manual 1178.3370.02 ─ 09
//to a new channel. The new channel is named 'Spectrum2' to avoid a naming conflict
//with the existing 'Spectrum' channel.
INST:REN 'Spectrum2','Spectrum3'
//Renames the loaded channel to 'Spectrum3'.
11.10
Configuring the R&S
FPL1000
The remote commands required to set up the R&S
FPL1000 are described here.
Configuring the Reference Frequency
.................................................................. 955
.........................................................................................955
.....................................................................................958
............................................................................ 962
Remote Commands for Language Settings
..........................................................967
Configuring the Network and Remote Control
...................................................... 967
Checking the System Configuration
......................................................................971
....................................................................................... 975
11.10.1
Configuring the Reference Frequency
........................................................................................ 955
[SENSe:]ROSCillator:SOURce
<Source>
This command selects the reference oscillator.
If you want to select the external reference, it must be connected to the R&S
FPL1000.
Parameters:
<Source>
INTernal
The internal reference is used (10 MHz)
EXTernal
The external reference from the "REF INPUT 10
MHZ" connec-
tor is used; if none is available, an error flag is displayed in the
status bar
Example:
ROSC:SOUR EXT
11.10.2
Calibration and Checks
The following commands control calibration and checks on the R&S
FPL1000.
DIAGnostic:SERVice:INPut:PULSed:CFRequency
............................................................ 956
DIAGnostic:SERVice:INPut:PULSed:MCFRequency
..........................................................957
DIAGnostic:SERVice:INPut:RF[:SPECtrum]
......................................................................957
Configuring the R&S