The Spectrum Application (RF Measurements)
R&S
®
FPL1000
375
User Manual 1178.3370.02 ─ 09
If the detector mode for the marker trace is set to "Auto", the RMS detector is used.
The individual marker settings correspond to those defined in the "Marker" dialog box
(see
Chapter 7.9.2.1, "Individual Marker Setup"
on page 349). Any settings to the
marker state or type changed in the "Marker Function" dialog box are also changed in
the "Marker" dialog box and vice versa.
Remote commands:
"Example: Measuring the Power in a Channel Using Band Power Markers"
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe]
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer:RESult?
................................................................................ 375
Switching All Band Power Measurements Off
.............................................................376
Band Power Measurement State
Activates or deactivates band power measurement for the marker in the diagram.
Band power markers are only available for standard frequency measurements (not
zero span) in the Spectrum application.
If activated, the markers display the power or density measured in the band around the
current marker position.
For details see
Chapter 7.9.4.6, "Measuring the Power in a Channel (Band Power
Remote command:
CALCulate<n>:MARKer<m>:FUNCtion:BPOWer[:STATe]
CALCulate<n>:DELTamarker<m>:FUNCtion:BPOWer[:STATe]
Marker Usage