![Ronde & Schwarz 1304.0004.03 User Manual Download Page 858](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985858.webp)
Remote Commands
R&S
®
FPL1000
858
User Manual 1178.3370.02 ─ 09
If necessary, the command activates the delta marker first.
Suffix:
<n>
.
<m>
Return values:
<Position>
Position of the delta marker in relation to the reference marker.
Example:
CALC:DELT3:X:REL?
Outputs the frequency of delta marker 3 relative to marker 1 or
relative to the reference position.
Usage:
Query only
Manual operation:
See
"Marker 1/Marker 2/Marker 3/Marker 4"
See
CALCulate<n>:DELTamarker<m>:Y
Queries the result at the position of the specified delta marker.
Suffix:
<n>
.
1..n
<m>
1..n
Return values:
<Result>
Result at the position of the delta marker.
The unit is variable and depends on the one you have currently
set.
Default unit: DBM
CALCulate<n>:MARKer<m>:Y
Queries the result at the position of the specified marker.
Suffix:
<n>
.
1..n
<m>
1..n
Return values:
<Result>
Default unit: DBM
Manual operation:
See
See
11.8.8.6
Marker Search (Spectrograms)
The following commands automatically define the marker and delta marker position in
the spectrogram.
Setting Basic Spectrum RF Measurement Parameters