![Ronde & Schwarz 1304.0004.03 User Manual Download Page 529](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985529.webp)
General Instrument Setup
R&S
®
FPL1000
529
User Manual 1178.3370.02 ─ 09
Name
Defines the transducer line name. All names must be compatible with the Windows
conventions for file names. The transducer data is stored under this name (with a
.TDF
extension) in the
C:\ProgramData\Rohde-Schwarz\ZNL-FPL\trd
directory.
Remote command:
[SENSe:]CORRection:TRANsducer:SELect
Comment
Defines an optional comment for the transducer line. The text may contain up to 40
characters.
Remote command:
[SENSe:]CORRection:TRANsducer:COMMent
Unit
The unit in which the y-values of the data points of the transducer line are defined.
As soon as a transducer is activated, the unit of the transducer is automatically used
for all the level settings and outputs. The unit cannot be changed in the amplitude set-
tings unless dB is used.
Remote command:
[SENSe:]CORRection:TRANsducer:UNIT
X-Axis Scaling
Describes the scaling of the horizontal axis on which the data points of the transducer
line are defined. Scaling can be linear or logarithmic.
Remote command:
[SENSe:]CORRection:TRANsducer:SCALing
Data Points
Each transducer line is defined by a minimum of 2 and a maximum of 50 data points.
Each data point is defined by its position (x-axis) and value (y-value).
The data points must comply with the following rules to ensure correct operation:
●
The frequencies for the data points must always be defined in ascending order.
Otherwise the entry will not be accepted and the an error message is displayed.
●
The frequencies of the data points may exceed the valid frequency range of the
R&S
FPL1000 since only the set frequency range is taken into account for mea-
surements. The minimum frequency of a data point is 0 Hz, the maximum fre-
quency 200 GHz.
●
The value range for the transducer factor is ±200 dB.
●
Gain has to be entered as a negative value, and attenuation as a positive value.
Remote command:
[SENSe:]CORRection:TRANsducer:DATA