![Ronde & Schwarz 1304.0004.03 User Manual Download Page 768](http://html1.mh-extra.com/html/ronde-and-schwarz/1304-0004-03/1304-0004-03_user-manual_1484985768.webp)
Remote Commands
R&S
®
FPL1000
768
User Manual 1178.3370.02 ─ 09
Parameters:
<Bandwidth>
Range:
10 Hz to Max span
*RST:
(= span/10 on activating the function)
Default unit: Hz
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:STRack:THReshold
<Level>
This command defines the threshold level for the signal tracking process.
Note that you have to turn on signal tracking before you can use the command.
Suffix:
<n>
.
irrelevant
<m>
irrelevant
Parameters:
<Level>
The unit depends on
Range:
-130 dBm to 30 dBm
*RST:
-120 dBm
Default unit: DBM
Manual operation:
See
CALCulate<n>:MARKer<m>:FUNCtion:STRack:TRACe
<TraceNumber>
This command selects the trace on which the largest signal is searched for.
Suffix:
<n>
.
irrelevant
<m>
irrelevant
Parameters:
<TraceNumber>
1 to 6
Range:
1 to 6
*RST:
1
Manual operation:
See
11.8.2
Configuring Bandwidth and Sweep Settings
The commands required to configure the bandwidth, sweep and filter settings in a
remote environment are described here. The tasks for manual operation are described
in
Chapter 7.6, "Bandwidth, Filter and Sweep Configuration"
Configuring the Bandwidth and Filter
....................................................................769
..........................................................................................772
Setting Basic Spectrum RF Measurement Parameters