User Manual 1178.3370.02 ─ 09
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
<Level>
This command defines the lower limit of a particular power class.
Note:
●
The first power class always has a lower limit of -200
dBm.
●
The lower limit of a power class must always be the same as the upper limit of the
previous power class.
●
The power class must already exist (see
ESPectrum<sb>:PCLass<pc>:COUNt
Suffix:
<n>
.
irrelevant
<li>
irrelevant
<sb>
1 to 3
<pc>
1..n
power class
Parameters:
<Level>
Range:
-200 dBm to 199.9 dBm
Default unit: dBm
Example:
CALC:LIM:ESP:PCL2:MIN -40 dBm
Sets the minimum power value of the second power class to -40
dBm.
Manual operation:
See
11.6.7.7
Configuring the List Evaluation
The following commands configure the list evaluation.
Useful commands for SEM measurements described elsewhere
●
Remote commands exclusive to SEM measurements
CALCulate<n>:ESPectrum:PSEarch:AUTO
...................................................................... 683
CALCulate<n>:ESPectrum:PEAKsearch:AUTO
.................................................................683
CALCulate<n>:ESPectrum:PSEarch[:IMMediate]
.............................................................. 684
CALCulate<n>:ESPectrum:PEAKsearch[:IMMediate]
.........................................................684
CALCulate<n>:ESPectrum:PSEarch:MARGin
...................................................................684
CALCulate<n>:ESPectrum:PEAKsearch:MARGin
............................................................. 684
CALCulate<n>:ESPectrum:PSEarch:PSHow
.................................................................... 684
CALCulate<n>:ESPectrum:PEAKsearch:PSHow
...............................................................684
CALCulate<n>:ESPectrum:PSEarch:AUTO
<State>
CALCulate<n>:ESPectrum:PEAKsearch:AUTO
<State>
This command turns the list evaluation on and off.
Configuring and Performing Measurements