728
22.11.2
Programmer Mode Operation
Table 22.11 shows how the different operating modes are set when using programmer mode, and
table 22.12 lists the commands used in programmer mode. Details of each mode are given below.
•
Memory Read Mode
Memory read mode supports byte reads.
•
Auto-Program Mode
Auto-program mode supports programming of 128 bytes at a time. Status polling is used to
confirm the end of auto-programming.
•
Auto-Erase Mode
Auto-erase mode supports automatic erasing of the entire flash memory. Status polling is used
to confirm the end of auto-programming.
•
Status Read Mode
Status polling is used for auto-programming and auto-erasing, and normal termination can be
confirmed by reading the I/O6 signal. In status read mode, error information is output if an
error occurs.
Table 22.11 Settings for Various Operating Modes In Programmer Mode
Pin names
Mode
FWE
CE
OE
WE
I/O7–0
A17–0
Read
H or L
L
L
H
Data output Ain
Output disable
H or L
L
H
H
Hi-z
Ain
Command write
H or L
L
H
L
Data input
*
Ain
Chip disable
H or L
H
X
X
Hi-z
Ain
Notes:
*
Ain indicates that there is also address input in auto-program mode.
1. Chip disable is not a standby state; internally, it is an operation state.
2. For command writes in auto-program and auto-erase modes, input a high level to the
FWE pin.
Summary of Contents for SH7041 Series
Page 2: ......
Page 6: ......
Page 38: ...xvi ...
Page 44: ...6 ...
Page 46: ...8 ...
Page 48: ...10 ...
Page 82: ...44 ...
Page 114: ...76 ...
Page 118: ...80 ...
Page 124: ...86 ...
Page 170: ...132 ...
Page 250: ...212 ...
Page 492: ...454 ...
Page 506: ...468 ...
Page 604: ...566 ...
Page 684: ...646 ...
Page 706: ...668 ...
Page 778: ...740 ...
Page 780: ...742 ...
Page 818: ...780 ...
Page 850: ...812 ...
Page 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...