
442
(28) Operation when Error Occurs during Reset-Synchronous PWM Mode Operation, and
Operation is Restarted in Reset-Synchronous PWM Mode: Figure 12.124 shows an
explanatory diagram of the case where an error occurs in reset-synchronous PWM mode and
operation is restarted in reset-synchronous PWM mode after re-setting.
1
RESET
2
TOCR
3
TMDR
(RPWM)
5
PFC
(MTU)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
PFC
(MTU)
12
TSTR
(1)
13
Match
MTU output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
High-Z
High-Z
High-Z
High-Z
High-Z
High-Z
Figure 12.124 Error Occurrence in Reset-Synchronous PWM Mode,
Recovery in Reset-Synchronous PWM Mode
1 to 10 are the same as in figure 12.121.
11.Set MTU output with the PFC.
12.Operation is restarted by TSTR.
13.The reset-synchronous PWM waveform is output on compare-match occurrence.
Summary of Contents for SH7041 Series
Page 2: ......
Page 6: ......
Page 38: ...xvi ...
Page 44: ...6 ...
Page 46: ...8 ...
Page 48: ...10 ...
Page 82: ...44 ...
Page 114: ...76 ...
Page 118: ...80 ...
Page 124: ...86 ...
Page 170: ...132 ...
Page 250: ...212 ...
Page 492: ...454 ...
Page 506: ...468 ...
Page 604: ...566 ...
Page 684: ...646 ...
Page 706: ...668 ...
Page 778: ...740 ...
Page 780: ...742 ...
Page 818: ...780 ...
Page 850: ...812 ...
Page 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...