693
Bit:
7
6
5
4
3
2
1
0
FLER
—
ESU2
PSU2
EV2
PV2
E2
P2
Initial value:
0
0
0
0
0
0
0
0
R/W:
R
R
R/W
R/W
R/W
R/W
R/W
R/W
•
Bit 7—Flash Memory Error (FLER): Indicates that an error has occurred during an operation
on flash memory (programming or erasing). When FLER is set to 1, flash memory goes to the
error-protection state.
Bit 7: FLER
Description
0
Flash memory is operating normally. (Initial value)
Flash memory program/erase protect (error protect) disabled
1
Indicates error during flash memory program/erase.
Flash memory program/erase protect (error protect) enabled
[Setting condition] See section 22.8.3, Error protection
•
Bit 6—Reserved bit: This bit is always read as 0.
•
Bit 5—Erase Setup Bit 2 (ESU2): Prepares for a transition to erase mode (applicable
addresses: H'20000–H'3FFFF). Do not set the PSU2, EV2, PV2, E2, or P2 bit at the same time.
Bit 5: ESU2
Description
0
Erase setup release (Initial value)
1
Erase setup
[Setting condition] When FWE=1 and SWE=1
•
Bit 4—Program Setup Bit 2 (PSU2): Prepares for a transition to program mode (applicable
addresses: H'20000–H'3FFFF). Do not set the ESU2, EV2, PV2, E2, or P2 bit at the same time.
Bit 4: PSU2
Description
0
Program setup release (Initial value)
1
Program setup
[Setting condition] When FWE=1 and SWE=1
Summary of Contents for SH7041 Series
Page 2: ......
Page 6: ......
Page 38: ...xvi ...
Page 44: ...6 ...
Page 46: ...8 ...
Page 48: ...10 ...
Page 82: ...44 ...
Page 114: ...76 ...
Page 118: ...80 ...
Page 124: ...86 ...
Page 170: ...132 ...
Page 250: ...212 ...
Page 492: ...454 ...
Page 506: ...468 ...
Page 604: ...566 ...
Page 684: ...646 ...
Page 706: ...668 ...
Page 778: ...740 ...
Page 780: ...742 ...
Page 818: ...780 ...
Page 850: ...812 ...
Page 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...