421
(8) Operation when Error Occurs during PWM Mode 1 Operation, and Operation is
Restarted in PWM Mode 1: Figure 12.103 shows an explanatory diagram of the case where an
error occurs in PWM mode 1 and operation is restarted in PWM mode 1 after re-setting.
1
RESET
2
TMDR
(PWM1)
3
TOER
(1)
5
PFC
(MTU)
4
TIOR
(1 init
0 out)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PWM1)
12
TIOR
(1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
MTU output
TIOC
*
A
TIOC
*
B
Port output
PEn
PEn
• Not initialized (TIOC
*
B)
• Not initialized (TIOC
*
B)
n=0 to 15
High-Z
High-Z
Figure 12.103 Error Occurrence in PWM Mode 1, Recovery in PWM Mode 1
1 to 10 are the same as in figure 12.102.
11.Not necessary when restarting in PWM mode 1.
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC*B side is not initialized.)
13.Set MTU output with the PFC.
14.Operation is restarted by TSTR.
Summary of Contents for SH7041 Series