375
TGCR
UF bit
VF bit
WF bit
TIOC3B pin
TIOC3D pin
TIOC4A pin
TIOC4C pin
TIOC4B pin
TIOC4D pin
6-phase output
When BDC = 1, N = 1, P = 1, FB = 0, output active level = high
Figure 12.58 Example of Output Phase Switching by Means of UF, VF, WF Bit Settings (2)
•
A/D conversion start request setting
In complementary PWM mode, an A/D conversion start request can be issued using a TGR3A
compare-match or a compare-match on a channel other than channels 3 and 4.
When start requests using a TGR3A compare-match are set, A/D conversion can be started at
the center of the PWM pulse.
A/D conversion start requests can be set by setting the TTGE bit to 1 in the timer interrupt
enable register (TIER).