440
(26) Operation when Error Occurs during Reset-Synchronous PWM Mode Operation, and
Operation is Restarted in PWM Mode 1: Figure 12.122 shows an explanatory diagram of the
case where an error occurs in reset-synchronous PWM mode and operation is restarted in PWM
mode 1 after re-setting.
1
RESET
2
TOCR
3
TMDR
(RPWM)
5
PFC
(MTU)
4
TOER
(1)
6
TSTR
(1)
7
Match
8
Error
occurs
9
PFC
(PORT)
10
TSTR
(0)
11
TMDR
(PWM1)
12
TIOR
(1 init
0 out)
13
PFC
(MTU)
14
TSTR
(1)
MTU output
TIOC3A
TIOC3B
TIOC3D
Port output
PE9
PE8
PE11
• Not initialized (TIOC3B)
• Not initialized (TIOC3D)
High-Z
High-Z
High-Z
Figure 12.122 Error Occurrence in Reset-Synchronous PWM Mode,
Recovery in PWM Mode 1
1 to 10 are the same as in figure 12.121.
11. Set PWM mode 1. (MTU positive phase output is low, and negative phase output is high.)
12. Initialize the pins with TIOR. (In PWM mode 1, the TIOC *B side is not initialized.)
13.Set MTU output with the PFC.
14.Operation is restarted by TSTR.
Summary of Contents for SH7041 Series
Page 2: ......
Page 6: ......
Page 38: ...xvi ...
Page 44: ...6 ...
Page 46: ...8 ...
Page 48: ...10 ...
Page 82: ...44 ...
Page 114: ...76 ...
Page 118: ...80 ...
Page 124: ...86 ...
Page 170: ...132 ...
Page 250: ...212 ...
Page 492: ...454 ...
Page 506: ...468 ...
Page 604: ...566 ...
Page 684: ...646 ...
Page 706: ...668 ...
Page 778: ...740 ...
Page 780: ...742 ...
Page 818: ...780 ...
Page 850: ...812 ...
Page 923: ...SH7040 SH7041 SH7042 SH7043 SH7044 SH7045 Group Hardware Manual REJ09B0044 0600O ...