IGNITION COIL TESTS
The ignition coil can be tested by using an ohm meter.
Use the following illustration and specification table to
test the ignition coil resistance.
Ignition Coil Resistance Readings
TEST
PIN CONNECTION
RESISTANCE
Primary
Between 1 & 2
Between 2 & 3
0.4 Ω
Secondary
(PTO)
Between High Tension
Lead Caps
2.30k Ω ± 5%
Secondary
(MAG)
Between High Tension
Lead Caps
2.73k Ω ± 5%