Expansion Valve:
The expansion valve
t
controls the
amount of refrigerant entering the evaporator coil.
Heater / Evaporator Unit:
The heater / evaporator unit
y
is located below the dash on the passenger side. The
unit delivers the cold air for the A/C and warm air for heat
into the cab. The unit contains the heat and A/C coils,
thermostat, and expansion valve.
Heater Coil:
The heater coil
u
supplies the warm air into
the cab by passing air through the coil.
Evaporator Coil:
The evaporator coil
i
cools and
dehumidifies the air before it enters the cab.
Thermostat:
The thermostat
o
and probe
a
controls
the temperature of the evaporator coil.
Heater / Evaporator Blower:
The blower
s
is used to
pull air through the heater and evaporator coils and into
the cab.
Control
Panel:
The
panel
has
three
separate
components.
Fan Switch:
This is a four position rotary switch
d
.
When the fan switch is in the off position the A/C will not
engage, but the heater valve will operate, as it is
controlled by the ignition power.
A/C Switch:
The rocker switch
f
will be illuminated
when the A/C is engaged.
Potentiometer:
The potentiometer
g
controls the
Heater Valve from fully Off to fully On. This can be used
in conjunction with the A/C for defrost of the windows and
temperature control.
Summary of Contents for RANGER XP 1000 2018-2019
Page 555: ...2018 19 RANGER 900 XP EPS CHASSIS...
Page 556: ...2018 RANGER 1000 XP CREW EPS CHASSIS...
Page 557: ...2018 19 RANGER 900 XP EU...
Page 558: ...2018 RANGER 1000 XP EPS HVAC CHASSIS...
Page 559: ...2018 RANGER 1000 XP MUDDER...
Page 560: ...2018 RANGER 1000 XP EPS CHASSIS...