TESTING VOLTAGE DROP
NOTICE
If you disconnect the connector at the load, and
measure voltage with one lead on the power supply
wire, and one to ground, you will be measuring
available voltage. This is a static test and not dynamic
voltage drop testing. Refer to page Static and Dynamic
The measurement of voltage is the
DIFFERENCE
in
electrical pressure between the two points your DMM
leads are touching.
Most circuits will have one load. The load is the
component in the circuit that uses the current flow to do
work, such as move a solenoid or light a bulb.
Voltage coming into the load should be near battery
voltage with current flowing. There will be some loss from
moving through electrical contacts in connectors and
relays, but it will be minimal.
NOTICE
You will need to backprobe to perform this test. For
information about doing this safely, refer to Connector
Voltage should be near fully depleted by the load. This
means that when measuring on the ground side of the
circuit, immediately after the load, back to battery
negative, you should have near zero pressure difference
(voltage).
If you do have a difference in pressure, this means there
is something adding resistance to the circuit such as
corrosion.
For a video demonstration, scan the QR code below, or
right click it and select “open in new tab”.
Summary of Contents for RANGER XP 1000 2018-2019
Page 555: ...2018 19 RANGER 900 XP EPS CHASSIS...
Page 556: ...2018 RANGER 1000 XP CREW EPS CHASSIS...
Page 557: ...2018 19 RANGER 900 XP EU...
Page 558: ...2018 RANGER 1000 XP EPS HVAC CHASSIS...
Page 559: ...2018 RANGER 1000 XP MUDDER...
Page 560: ...2018 RANGER 1000 XP EPS CHASSIS...