3.134
9929399 R01 - 2018-2019
RANGER
XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.
CONDENSER REPLACEMENT
1.
Remove the refrigerant from the A/C system.
WARNING
In the event of a leak, wear safety goggles. Escaping
refrigerant can cause severe injuries to eyes. In contact
with a flame, R-134a refrigerant gives a toxic gas.
2.
Remove the left rear fender.
3.
Disconnect the outlet hose
q
from the condenser.
4.
Disconnect the inlet tube
w
from the condenser
5.
Cap and plug the tube and the condenser fittings
with the proper A/C caps and plugs.
6.
Remove the two bolts
e
and move the drier out of
the way.
7.
Remove the two bolts
r
from the bottom of the
condenser.
8.
Remove the bolt
t
from the top of the condenser.
9.
Remove the condenser from the vehicle.
10.
Installation:
Reverse procedure. Tighten fasteners
to specification.
TORQUE
Upper Condenser Hose:
18 ft-lb (24 Nm)
Lower Condenser / Receiver-Drier Hose:
12 ft-lb (16 Nm)
Condenser Upper Mounting Bolt:
14 ft-lb (19 Nm)
Condenser Lower Mounting Bolts:
8 ft-lb (11 Nm)
11. Recharge A/C system.