9929399 R01 - 2018-2019
RANGER
XP/ CREW 900/1000 Service Manual
© Copyright Polaris Industries Inc.
10.23
Center Mirror Removal / Installation
1. Remove the fasteners holding the mirror to the mount
bracket.
2. Remove the fasteners holding the mount bracket to
the wiper motor cover.
3. For installation, reverse removal procedure. Torque
the fasteners until taught. Do NOT over torque the
fasteners.
Windshield Wiper Removal / Installation
1. Remove the fasteners holding the wiper motor cover
to the assembly.
2. Disconnect the wiper fluid line and electrical switch
connectors from the wiper motor assembly.
3. Remove the fastener holding the windshield wiper
arm to the motor shaft.
4. Remove the seal and plug covering the wiper motor
shaft.
5. Remove the fastener holding the wiper motor
assembly
to
the
windshield
and
remove
the
assembly..
6. For installation, reverse the removal procedure and
torque the fasteners to specification.
TORQUE
Wiper Motor Shaft Fastener:
15 lb-ft (20 Nm)
Wiper Arm Fastener:
10 lb-ft (14 Nm)