STARTER SOLENOID OPERATION
To energize the Starter Solenoid the following must occur:
• The brake must be applied to close the brake pressure switch and provide 12V power to the key switch and ECU.
• The key switch must be turned to the “start” position to provide 12V power to the starter solenoid via the Green /
White wire.
• Once the pull-in coil is energized, the solenoid provides a current path for 12V power to reach the starter motor.