Troubleshooting Using Status Indicators
Fan Module Fault
For a server with a fan module fault, the server amber Fault-Service Required LEDs (front and
back) and an amber Fault-Service Required LED on a fan module are on steady. The front and
back green On Standby, server OK indicator and the green SP indicator are on steady.
Service Processor Fault
For a server with an SP (service processor) fault, the server amber Fault-Service Required
LEDs (front and back) are on steady. The front and back System OK indicators and the SP OK
indicator are off.
Front Panel Lamp Test
To perform a lamp test of all front panel indicators, press the Locate Button/LED button three
times within a five second period. All the front and back indicators light up and remain on
).
Back Panel Pinhole Switches
This section shows the location of the back panel pinhole switches.
Call
Out
Button
Icon
Description
1
Non-maskable Interrupt (NMI)
button (recessed) SMOD0
Do not press. This button is used by Oracle Service personnel only and
requires a stylus.
76
Oracle Server X7-8 Service Manual • October 2017
Summary of Contents for X7-8
Page 1: ...Oracle Server X7 8 Service Manual Part No E71936 01 October 2017 ...
Page 2: ......
Page 13: ...Contents Index 303 13 ...
Page 14: ...14 Oracle Server X7 8 Service Manual October 2017 ...
Page 16: ...16 Oracle Server X7 8 Service Manual October 2017 ...
Page 46: ...46 Oracle Server X7 8 Service Manual October 2017 ...
Page 268: ...268 Oracle Server X7 8 Service Manual October 2017 ...
Page 294: ...294 Oracle Server X7 8 Service Manual October 2017 ...