System Sensors Network Access Control (NAC) Names
Name (1x8)
Name (2x4-A Side)
Name (2x4-B Side)
Description
/SYS/FM[0-7]/F[0/1]/
TACH
/SYS/FM[0-3]/F[0/1]/
TACHThreshold
/SYS/FM[4-7]/
F[0/1]/TACH
Fan speed. RPM
/SYS/DPCC[0-7]/PRSNT
/SYS/DPCC[0-3]/
PRSNT
/SYS/DPCC[4-7]/
PRSNT
Discrete DPCC Carrier presence.
01h: Absent 02h: Present
/SYS/DPCC[0-7]/PRSNT
/SYS/DPCC[0-3]/
PRSNT
/SYS/DPCC[4-7]/
PRSNT
Discrete DPCC Carrier presence.
01h: Absent 02h: Present
/SYS/DPCC[0-7]/
PCIE[1-16]/PRSNT
/SYS/DPCC[0-3]/
PCIE[1-8]/PRSNT
/SYS/DPCC[4-7]/
PCIE[9-16]/PRSNT
Discrete PCIE card presence. 01h:
Absent 02h: Present
/SYS/CMOD[0-7]/P[0-7]/
PRSNT
/SYS/CMOD[0-3]/
P[0-3]/PRSNT
/SYS/CMOD[4-7]/
P[4-7]/PRSNT
Discrete Processor presence. 01h:
Absent 02h: Present
/SYS/CMOD[0-7]/PRSNT
/SYS/CMOD[0-3]/
PRSNT
/SYS/CMOD[4-7]/
PRSNT
Discrete CPU module motherboard
presence. 01h: Absent 02h: Present
/SYS/CMOD[0-7]/P[0-7]/
D[0-11]/PRSNT
/SYS/CMOD[0-3]/
P[0-3]/D[0-11]/
PRSNT
/SYS/CMOD[4-7]/
P[4-7]/D[0-11]/
PRSNT
Discrete DIMM presence (hidden)
01h: Absent 02h: Present
/SYS/CMOD[0-7]/T_IN
/SYS/CMOD[0-3]/
T_IN
/SYS/CMOD[4-7]/
T_IN
Threshold CMOD inlet ambient
temperature Degree in C
/SYS/CMOD[0-7]/
T_IN_DPCC
/SYS/CMOD[0-3]/
T_IN_DPCC
/SYS/CMOD[4-7]/
T_IN_DPCC
Threshold Inlet air temperature to the
DPCC connector. Degree in C
/SYS/CMOD[0-7]/
T_IN_HDD
/SYS/CMOD[0-3]/
T_IN_HDD
/SYS/CMOD[4-7]/
T_IN_HDD
Threshold Inlet air temperature to the
HDD Disk Riser. Degree in C
/SYS/CMOD[0-7]/
T_OUT_CPU
/SYS/CMOD[0-3]/
T_OUT_CPU
/SYS/CMOD[4-7]/
T_OUT_CPU
Threshold CMOD temperature
behind CPU Degree in C
/SYS/SMOD[0-1]/MB/
T_IN
/SYS/SMOD0/MB/
T_IN
/SYS/SMOD1/MB/
T_IN
Threshold SMOD Inlet air
temperature near midplane
connectors. Degree in C
/SYS/SMOD[0-1]/MB/
T_HBA
/SYS/SMOD0/MB/
T_HBA
/SYS/SMOD1/MB/
T_HBA
Threshold SMOD temperature on
bottomside HBA location. Degree in
C
/SYS/SMOD[0-1]/MB/
T_PHY
/SYS/SMOD0/MB/
T_PHY
/SYS/SMOD1/MB/
T_PHY
Threshold SMOD temperature on
topside network PHY chip. Degree
in C
/SYS/SMOD[0-1]/MB/
T_OUT
/SYS/SMOD0/MB/
T_OUT
/SYS/SMOD1/MB/
T_OUT
Threshold SMOD temperature on
topside rear outlet. Degree in C
/SYS/PS[0-3]/PRSNT
/SYS/PS[2-3]/PRSNT
/SYS/PS[0-1]/
PRSNT
Discrete Power supply presence 01h:
Absent 02h: Present
/SYS/PS[0-3]/P_IN/
SYS/PS[2-3]/P_IN
/SYS/PS[0-1]/P_IN
Threshold PS input power
consumption Watts
/SYS/PS[0-3]/P_OUT
/SYS/PS[2-3]/P_OUT
/SYS/PS[0-1]/
P_OUT
Threshold PS output power Watts
/SYS/PS[0-3]/STATE
/SYS/PS[2-3]/STATE
/SYS/PS[0-1]/STATE Discrete IPMI Standard Power
Supply Sensor 01h: No Fault 02h:
Fault
Monitoring and Identifying Server Components
301
Summary of Contents for X7-8
Page 1: ...Oracle Server X7 8 Service Manual Part No E71936 01 October 2017 ...
Page 2: ......
Page 13: ...Contents Index 303 13 ...
Page 14: ...14 Oracle Server X7 8 Service Manual October 2017 ...
Page 16: ...16 Oracle Server X7 8 Service Manual October 2017 ...
Page 46: ...46 Oracle Server X7 8 Service Manual October 2017 ...
Page 268: ...268 Oracle Server X7 8 Service Manual October 2017 ...
Page 294: ...294 Oracle Server X7 8 Service Manual October 2017 ...