System Indicators Network Access Control (NAC) Names
Name (1x8)
Name (2x4-A Side)
Name (2x4-B
Side)
Description
Rear FRU have a fault. Off: Rear
FRUs have no fault.
/SYS/SMOD0/MB/SP/OK
(A-Side; B-side disabled)
/SYS/SMOD0/MB/SP/OK
/SYS/SMOD1/
MB/SP/OK
SP OK Color: Green Location:
FIM Front Panel and SMOD
rear panel On: SP is normal. Fast
Blink: SP is booting. Off: SP has
no power.
/SYS/CMOD[0-7]/SERVICE /SYS/CMOD[0-3]/
SERVICE
/SYS/
CMOD[4-7]/
SERVICE
CMOD Service Color: Amber
Location: FIM Front Panel On:
CMOD has fault. Off: CMOD
has no fault.
/SYS/CMOD[0-7]/P[0-7]/
SERVICE
IPMI short name: CMODx/P
[0-7]/SVC
/SYS/CMOD[0-3]/P[0-3]/
SERVICE
IPMI short name: CMODx/
P[0-3]/SVC
/SYS/
CMOD[4-7]/
P[4-7]/SERVICE
IPMI short name:
CMODx/P[0-3]/
SVC
Processor Service Color:
Amber Location: CMOD board.
On: Processor has fault. Off:
Processor has no fault.
/SYS/CMOD[0-7]/P[0-7]/
D[0-11]/SERVICE IPMI
short name: CMODx/P[0-7]/
Dxx/SVC
/SYS/CMOD[0-3]/P[0-3]/
D[0-11]/SERVICE IPMI
short name: CMODx/
P[0-3]/Dxx/SVC
/SYS/
CMOD[4-7]/
P[4-7]/D[0-11]/
SERVICE IPMI
short name:
CMODx/P[4-7]/
Dxx/SVC
Memory Service Color: Amber
Location: CMOD board. On:
DIMM has fault. Off: DIMM has
no fault.
/SYS/SMOD[0-1]/SERVICE
/SYS/SMOD0/SERVICE
/SYS/SMOD1/
SERVICE
SMOD Fault Color: Amber
Location: SMOD Back Panel
On: SMOD has fault. Off:
SMOD has no fault.
/SYS/SMOD[0-1]/OK
/SYS/SMOD0/OK
/SYS/SMOD1/OK SMOD OK Color: Green
Location: SMOD Back Panel
On: SMOD is functional. Off:
SMOD not working or not
active. In 1x8 mode, SMOD1
OK LED will be off.
/SYS/SMOD[0-1]/HBA/
SERVICE
/SYS/SMOD0/HBA/
SERVICE
/SYS/SMOD1/
HBA/SERVICE
HBA Fault Color: Amber
Location: SMOD Back Panel
On: HBA has fault. Off: HBA
has no fault.
/SYS/DPCC[0-7]/
PCIE[1-16]/OK
/SYS/DPCC[0-3]/
PCIE[1-8]/OK
/SYS/DPCC[4-7]/
PCIE[9-16]/OK
PCIe OK Color: Green Location:
DPCC PCIe On: PCIe is in use.
Blink: PCIe is in transition.
Off: Ready to be removed
(conditional).
/SYS/DPCC[0-7]/
PCIE[1-16]/SERVICE
/SYS/DPCC[0-3]/
PCIE[1-8]/SERVICE
/SYS/DPCC[4-7]/
PCIE[9-16]/
SERVICE
PCIe Service Color: Amber
Location: DPCC PCIe On: PCIe
has fault. Off: PCIe has no fault.
Fast Blink: Locate
Monitoring and Identifying Server Components
299
Summary of Contents for X7-8
Page 1: ...Oracle Server X7 8 Service Manual Part No E71936 01 October 2017 ...
Page 2: ......
Page 13: ...Contents Index 303 13 ...
Page 14: ...14 Oracle Server X7 8 Service Manual October 2017 ...
Page 16: ...16 Oracle Server X7 8 Service Manual October 2017 ...
Page 46: ...46 Oracle Server X7 8 Service Manual October 2017 ...
Page 268: ...268 Oracle Server X7 8 Service Manual October 2017 ...
Page 294: ...294 Oracle Server X7 8 Service Manual October 2017 ...