393
Data Memory Coding Sheets
Appendix C
Note
m=20000+ unit number x 100 is allocated as the DM number.
DM word
Setting contents
15
8
7
0
m
m+1
m+2
m+3
m+4
m+5
m+6
m+7
m+8
m+9
m+10
m+11
m+12
m+13
m+14 to m+17
m+18
m+19
m+20
m+21
m+22
m+23 to m+26
m+27
m+28
m+29
m+30
m+31
m+32
m+33
m+34
m+35
Ratio conversion
use designation
Input use
designation
Output use
designation
Input signal range setting Output signal range setting
---
---
Output 1: Output status
when conversion stopped
Output 2: Output status
when conversion stopped
---
---
Input 1: Mean value processing setting
Input 2: Mean value processing setting
Input 3: Mean value processing setting
Input 4: Mean value processing setting
Loop 1 (input 1
→
output 1), A constant
Loop 1 (input 1
→
output 1), B constant
Loop 2 (input 1
→
output 1), A constant
Loop 2 (input 1
→
output 1), B constant
---
Output 1 scaling lower limit
Output 1 scaling upper limit
Output 2 scaling lower limit
Output 2 scaling upper limit
Input 1 scaling lower limit
Input 1 scaling upper limit
Input 2 scaling lower limit
Input 2 scaling upper limit
Input 3 scaling lower limit
Input 3 scaling upper limit
Input 4 scaling lower limit
Input 4 scaling upper limit
Voltage/current range setting
(Valid for 1 to 5 V or 4 to 20 mA.)
---
---
Input
Output
15 12 11 08
07 04 03 00
07 06 05 04 03 02 01 00
Use Designation
0: Do not use.
1: Use
15 12 11 10 09 08
00: Do not use.
01: Positive gradient conversion
10: Negative gradient conversion
11: Same as the above "00" setting
Signal Range Setting
07 03 02 01 00
15 14 13 12 11 10 09 08
00:
−
10 to 10 V
01: 0 to 10 V
10: 1 to 5 V/4 to 20 mA
11: 0 to 5 V
07 04 03 00
16
1
16
0
00: CLR (0 or minimum value for each range output)
01: HOLD (Hold prior output value.)
02: MAX (Output maximum value of range.)
Output Status when Conversion Stopped
15 12 11 08 07 04 03 00
16
3
16
2
16
1
16
0
Mean Value Processing Setting
0000: Mean value processing with 2 buffers.
0001: No mean value processing
0002: Mean value processing with 4 buffers.
0003: Mean value processing with 8 buffers.
0004: Mean value processing with 16 buffers.
0005: Mean value processing with 32 buffers.
0006: Mean value processing with 64 buffers.
Conversion Time and Resolution Setting
Operation Mode
00: Conversion time = 1 ms, resolution = 4,000
C1: Conversion time = 500
µ
s, resolution = 8,000
00: Normal mode
C1: Adjustment mode
Conversion time/
resolution setting
Operation mode setting
---
Input
4
Input
3
Input
2
Input
1
Out-
put 2
Out-
put 1
Loop
1
Loop
2
Output
2
Output
1
Input
4
Input
3
Input
2
Input
1
Voltage/Current Specifications
(when 1 to 5 V/4 to 20 mA is selected)
15 08 07 06 05 04 03 02 01 00
This setting is valid for inputs and/or outputs
only if "10" (1 to 5 V/4 to 20 mA) was
specified in m+1.
Input
4
Input
3
Input
2
Input
1
Out-
put 2
Out-
put 1
0: Voltage (1 to 5 V)
1: Current (4 to 20 mA)
Summary of Contents for CJ1W-AD041-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 15: ...xvi...
Page 99: ...76 Handling Errors and Alarms Section 2 8...
Page 191: ...168 Handling Errors and Alarms Section 4 8...
Page 243: ...220 Handling Errors and Alarms Section 5 8...
Page 381: ...358 Handling Errors and Alarms Section 7 10...
Page 385: ...362 Dimensions Appendix A...
Page 395: ...372 Sample Programs Appendix B...
Page 396: ...373 Appendix C Data Memory Coding Sheets...
Page 417: ...394 Data Memory Coding Sheets Appendix C...
Page 425: ......