126
Specifications
Section 4-1
4-1
Specifications
4-1-1
Specifications
Note
1.
Do not apply a voltage higher than 600 V to the terminal block when per-
forming withstand voltage test on this Unit.
Item
CS1W-DA041
CS1W-DA08V
CS1W-DA08C
Unit type
CS-series Special I/O Unit
Isolation (See note 1.)
Between I/O and PLC signals: Photocoupler
(No isolation between individual I/O signals.)
External terminals
21-point detachable terminal block (M3 screws)
Power consumption
130 mA max. at 5 VDC,
180 mA max. at 26 VDC
130 mA max. at 5 VDC,
180 mA max. at 26 VDC
130 mA max. at 5 VDC,
250 mA max. at 26 VDC
Dimensions (mm)
(See note 2.)
35 x 130 x 126 (W x H x D)
Weight
450 g max.
General specifications
Conforms to general specifications for SYSMAC CS-series Series.
Mounting position
CS-series CPU Rack or CS-series Expansion Rack
(Cannot be mounted to a C200H Expansion I/O Rack or a SYSMAC BUS Slave Rack.)
Maximum number of Units (See
note 3.)
Depends on the Power Supply Unit.
Data exchange with CPU Units
(See note 4.)
Special I/O Unit Area
CIO 200000 to CIO295915
(Words CIO 2000 to CIO 2959)
Internal Special I/O Unit DM Area
(D20000 to D29599)
Output
specifi-
cations
Number of analog out-
puts
4
8
8
Output signal ranges
(See note 5.)
1 to 5 V/4 to 20 mA
0 to 5 V
0 to 10 V
–10 to 10V
1 to 5 V
0 to 5 V
0 to 10 V
–10 to 10 V
4 to 20 mA
Output impedance
0.5
Ω
max. (for voltage output)
Max. output current (for
1 point)
12 mA (for voltage output)
Maximum permissible
load resistance
600
Ω
(current output)
(See note 9.)
---
600
Ω
(current output)
(See note 8.)
Resolution
4,000 (full scale)
Set data
16-bit binary data
Accuracy
(See note 6.)
23
±
2
°
C:
Voltage output:
±
0.3% of full scale
Current output:
±
0.5% of full scale
0
°
C to 55
°
C:
Voltage output:
±
0.5% of full scale
Current output:
±
0.8% of full scale
D/A conversion time
(See note 7.)
1.0 ms/point max.
Output
func-
tions
Output hold function
Outputs the specified output status (CLR, HOLD, or MAX) under any of the following cir-
cumstances.
When the Conversion Enable Bit is OFF. (See note 8.)
In adjustment mode, when a value other than the output number is output during adjust-
ment.
When there is an output setting error or a fatal error occurs at the PLC.
When the CPU Unit is on standby.
When the Load is OFF.
Summary of Contents for CJ1W-AD041-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 15: ...xvi...
Page 99: ...76 Handling Errors and Alarms Section 2 8...
Page 191: ...168 Handling Errors and Alarms Section 4 8...
Page 243: ...220 Handling Errors and Alarms Section 5 8...
Page 381: ...358 Handling Errors and Alarms Section 7 10...
Page 385: ...362 Dimensions Appendix A...
Page 395: ...372 Sample Programs Appendix B...
Page 396: ...373 Appendix C Data Memory Coding Sheets...
Page 417: ...394 Data Memory Coding Sheets Appendix C...
Page 425: ......