363
Appendix B
Sample Programs
Obtaining Analog Input Conversion Values
This is a program for obtaining the Analog Input Unit’s input conversion values. Individual input values are
obtained by MOV(021) when their Disconnection Detection Flags are OFF.
Unit Settings
Program Example
Writing Analog Output Set Values
This is a program for writing the Analog Output Unit’s output set values.
Unit Settings
Item
Setting contents
Actual settings
Unit
CS1W-AD081-V1
---
Unit number
#0
Unit number switch: 00
Operation mode
Normal mode
Back-panel DIP switch: All OFF
Input number
Inputs 1 to 8 used
D20000 = 00FF
Input signal range
All input numbers, 1 to 5 V
D20001 = AAAA
200900
MOV(021)
2001
D00000
200901
MOV(021)
2002
D00001
Conversion value
Conversion value
200907
MOV(021)
2008
D00007
Conversion value
Input 1 Disconnection Detection Flag
Input 2 Disconnection Detection Flag
Input 8 Disconnection Detection Flag
Item
Setting contents
Actual settings
Unit
CS1W-DA08V
---
Unit number
#0
Unit number switch: 00
Operation mode
Normal mode
Back-panel DIP switch: All OFF
Output number
Output 1 used
D20000 = 0001
Output signal range
Output number 1, 0 to 10 V
D20001 = 0001
Summary of Contents for CJ1W-AD041-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 15: ...xvi...
Page 99: ...76 Handling Errors and Alarms Section 2 8...
Page 191: ...168 Handling Errors and Alarms Section 4 8...
Page 243: ...220 Handling Errors and Alarms Section 5 8...
Page 381: ...358 Handling Errors and Alarms Section 7 10...
Page 385: ...362 Dimensions Appendix A...
Page 395: ...372 Sample Programs Appendix B...
Page 396: ...373 Appendix C Data Memory Coding Sheets...
Page 417: ...394 Data Memory Coding Sheets Appendix C...
Page 425: ......