167
Handling Errors and Alarms
Section 4-8
4-8-5
Troubleshooting
The following tables explain the probable causes of troubles that may occur,
and the countermeasures for dealing with them.
Analog Output Does Not Change
Output Does Not Change as Intended
Outputs are Inconsistent
Probable Cause
Countermeasure
Page
The output is not set for being used. Set the output for being used.
The output hold function is in opera-
tion.
Turn ON the Output Conversion
Enable Bit.
The conversion value is set outside
of the permissible range.
Set the data within the range.
Probable Cause
Countermeasure
Page
The output signal range setting is
wrong.
Correct the output signal range set-
ting.
The specifications of the output
device do not match those of the
Analog Output Unit (e.g., input sig-
nal range, input impedance).
Change the output device.
The offset or gain is not adjusted.
Adjust the offset or gain.
Probable Cause
Countermeasure
Page
The output signals are being
affected by external noise.
Try changing the shielded cable
connection (e.g., the grounding at
the output device).
Summary of Contents for CJ1W-AD041-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 15: ...xvi...
Page 99: ...76 Handling Errors and Alarms Section 2 8...
Page 191: ...168 Handling Errors and Alarms Section 4 8...
Page 243: ...220 Handling Errors and Alarms Section 5 8...
Page 381: ...358 Handling Errors and Alarms Section 7 10...
Page 385: ...362 Dimensions Appendix A...
Page 395: ...372 Sample Programs Appendix B...
Page 396: ...373 Appendix C Data Memory Coding Sheets...
Page 417: ...394 Data Memory Coding Sheets Appendix C...
Page 425: ......