Specifications
Section 6-1
Note
1.
Refer to
Dimensions
on page 359 for details on the Unit’s dimensions.
Input
Specifications
Voltage input
Current input
Number of analog inputs
4
Input signal range (See note 3.)
1 to 5 V
0 to 5 V
0 to 10 V
–10 to 10 V
4 to 20 mA
(See note 4.)
Maximum rated input (for 1 point) (See note
5.)
±
15 V
±
30 mA
Input impedance
1 M
Ω
min.
250
Ω
(rated value)
Resolution
4,000 (full scale)
Converted output data
16-bit binary data
Accuracy
(See note 6.)
23
±
2
°
C
±
0.2% of full scale
±
0.4% of full scale
0
°
C to 55
°
C
±
0.4% of full scale
±
0.6% of full scale
A/D conversion time (See note 7.)
1.0 ms/point max.
Functions
Mean value process-
ing
Stores the last “n” data conversions in the buffer, and stores the
the mean value of the conversion values.
Buffer number: n = 2, 4, 8, 16, 32, 64
Peak value holding
Stores the maximum conversion value while the Peak Value Hold
Bit is ON.
Input disconnection
detection (See note
9.)
Detects the disconnection and turns ON the Disconnection Detec-
tion Flag.
Output
Specifications
Voltage output
Number of analog outputs
4
Output signal range
(See note 3.)
1 to 5 V
0 to 5 V
0 to 10 V
–10 to 10 V
Output impedance (for 1 point)
0.5
Ω
max.
Max. output current
12 mA
Resolution
4,000 (full scale)
Set data
16-bit binary data
Accuracy
(See note 6.)
23
±
2
°
C
±
0.3% of full scale
0
°
C to 55
°
C
±
0.5% of full scale
D/A conversion time (See note 7.)
1.0 ms/point max.
Functions
Output hold function
Outputs the specified output status (CLR, HOLD, or MAX) under
any of the following circumstances.
When the Conversion Enable Bit is OFF. (See note 8.)
In adjustment mode, when a value other than the output number is
output during adjustment.
When there is an output setting error or a fatal error occurs at the
PLC.
When the CPU Unit is on standby.
When the Load is OFF.
Other
Functions
Ratio conversion
function
Stores the results of positive and negative gradient analog inputs
calculated for ratio and bias as analog output values.
Positive gradient: Analog output = A
×
Analog input + B
(A = 0 to 99.99, B = 8,000 to 7FFF Hex)
Negative gradient: Analog output = F – A
×
Analog input + B
(A = 0 to 99.99, B = 8,000 to 7FFF Hex,
F = output range max. value)
Item
CS1W-MAD44
Summary of Contents for CJ1W-AD041-V1
Page 3: ...iv...
Page 5: ...vi...
Page 9: ...x TABLE OF CONTENTS...
Page 15: ...xvi...
Page 99: ...76 Handling Errors and Alarms Section 2 8...
Page 191: ...168 Handling Errors and Alarms Section 4 8...
Page 243: ...220 Handling Errors and Alarms Section 5 8...
Page 381: ...358 Handling Errors and Alarms Section 7 10...
Page 385: ...362 Dimensions Appendix A...
Page 395: ...372 Sample Programs Appendix B...
Page 396: ...373 Appendix C Data Memory Coding Sheets...
Page 417: ...394 Data Memory Coding Sheets Appendix C...
Page 425: ......